Show Hamamatsu Avalanche Photo Diode 0612004929 - Archived data from Wed, 27. November 2019 20:15:29 CET
This is all the information about APD 0612004929. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0612004929 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F08 |
| Break-through voltage: | 440 V |
| Voltage for Gain 100 (T=+25°C): | 412.3 V |
| Dark current: | 15.6 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 265 |
| Position in Box: | 24 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 638 |
| Position in grid: | 4 |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:22:28 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:44:30 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:49:43 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:35:14 CEST | jreher | Updated box and position via API. |
| 27. Nov 2019 20:15:29 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:30:42 CET | jreher | Updated box and position via API. |
| 25. Nov 2019 17:16:35 CET | spankonin | Updated APD batch assignment via API. |
| 27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
| 29. Sep 2017 09:51:59 CEST | markus.moritz | Entered arrival for irradiation date. |
| 21. Nov 2016 17:44:54 CET | Tobias | Assigned to grid via information extracted from APD DB. |
| 21. Nov 2016 17:19:44 CET | tobias | Manually added based on APD lab DB export. |