Show Hamamatsu Avalanche Photo Diode 2319025768 - Archived data from Thu, 16. January 2020 11:57:33 CET
This is all the information about APD 2319025768. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2319025768 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F10 |
| Break-through voltage: | 409 V |
| Voltage for Gain 100 (T=+25°C): | 381 V |
| Dark current: | 4.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 220 |
| Position in Box: | 31 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 21. Aug 2019 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:16:44 CET | jreher | Updated box and position via API. |
| 29. Jan 2021 10:27:11 CET | jreher | Assigned to capsule by script |
| 06. Oct 2020 16:52:33 CEST | jreher | Updated box and position via API. |
| 11. Aug 2020 17:42:35 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:27:40 CEST | jreher | Updated box and position via API. |
| 16. Jan 2020 12:06:06 CET | jreher | Updated date sent for analysis after screening via API. |
| 16. Jan 2020 12:04:17 CET | jreher | Updated annealing info via API. |
| 16. Jan 2020 12:01:27 CET | jreher | Updated irradiation info via API. |
| 16. Jan 2020 11:58:35 CET | jreher | Updated arrival for irradiation via API. |
| 16. Jan 2020 11:57:33 CET | jreher | Updated arrival for irradiation via API. |
| 27. Nov 2019 20:07:57 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:28:03 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 16:34:02 CEST | spankonin | Updated APD batch assignment via API. |
| 22. Oct 2019 16:12:04 CEST | spankonin | Updated APD location via API. |
| 23. Jun 2016 12:00:16 CEST | Tobias | Imported from Hamamatsu datasheet. |