Subdetector specification:  
Serial: 2316025503
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.2 V
Dark current: 8.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 22
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.1278738 V     T = -25 °C: 344.77763 V
Voltage for Gain 150: T = +20 °C: 387.9856297 V     T = -25 °C: 352.1689201 V
Voltage for Gain 200: T = +20 °C: 392.3837294 V     T = -25 °C: 356.3287113 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.535956664 V-1     T = -25 °C: 4.991599453 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.882232436 V-1     T = -25 °C: 9.251236537 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.41362576 V-1     T = -25 °C: 16.45366472 V-1
Break-through voltage: T = +20 °C: 408.2807239 V     T = -25 °C: 371.9166772 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:40 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:30:48 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:29:57 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:17:32 CET jreher Updated box and position via API.
11. Aug 2020 17:42:28 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:28:47 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:49 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:00 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:10 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:10 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:16 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:05 CET jreher Updated APD location via API.
25. Nov 2019 17:28:32 CET jreher Updated box and position via API.
22. Oct 2019 16:25:56 CEST spankonin Updated APD batch assignment via API.
22. Oct 2019 16:10:07 CEST spankonin Updated APD location via API.
23. Jun 2016 12:00:09 CEST Tobias Imported from Hamamatsu datasheet.