Show Hamamatsu Avalanche Photo Diode 2315025413 - Archived data from Tue, 11. August 2020 17:42:23 CEST
This is all the information about APD 2315025413. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2315025413 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | assigned to 2315025413/2311025082 |
| Unit: | #1152 (barcode 1309012879) |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | blue |
| Manufacturer information: | |
| Wafer position: | E04 |
| Break-through voltage: | 412 V |
| Voltage for Gain 100 (T=+25°C): | 384.3 V |
| Dark current: | 7.1 nA |
| Screening Logistics: | |
| Available: | No |
| Storage Box: | 226 |
| Position in Box: | 16 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 21. Aug 2019 |
| Sent for analysis after irradiation: | 15. Oct 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 09. Oct 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 12. Oct 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 384.1246162 V T = -25 °C: 348.5092533 V |
| Voltage for Gain 150: | T = +20 °C: 391.9694719 V T = -25 °C: 355.9660391 V |
| Voltage for Gain 200: | T = +20 °C: 396.3328744 V T = -25 °C: 360.1458857 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.573707915 V-1 T = -25 °C: 4.671932487 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 9.045211432 V-1 T = -25 °C: 9.430684285 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.01722841 V-1 T = -25 °C: 14.8593843 V-1 |
| Break-through voltage: | T = +20 °C: 411.50984 V T = -25 °C: 375.4442894 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:17:29 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:42:23 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:28:44 CEST | jreher | Updated box and position via API. |
| 03. Apr 2020 10:01:13 CEST | jreher | Assigned to capsule by script |
| 13. Feb 2020 14:24:11 CET | jreher | Updated box and position via API. |
| 16. Jan 2020 12:05:48 CET | jreher | Updated date sent for analysis after screening via API. |
| 16. Jan 2020 12:03:58 CET | jreher | Updated annealing info via API. |
| 16. Jan 2020 12:01:08 CET | jreher | Updated irradiation info via API. |
| 16. Jan 2020 11:58:06 CET | jreher | Updated arrival for irradiation via API. |
| 16. Jan 2020 11:57:14 CET | jreher | Updated arrival for irradiation via API. |
| 27. Nov 2019 20:09:03 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:28:30 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 16:25:25 CEST | spankonin | Updated APD batch assignment via API. |
| 22. Oct 2019 16:10:06 CEST | spankonin | Updated APD location via API. |
| 23. Jun 2016 12:00:06 CEST | Tobias | Imported from Hamamatsu datasheet. |