RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2314025336 - Archived data from Tue, 11. August 2020 17:41:03 CEST


This is all the information about APD 2314025336. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2314025336
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.9 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 231
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.338214 V     T = -25 °C: 350.608437 V
Voltage for Gain 150: T = +20 °C: 394.2450378 V     T = -25 °C: 358.1168083 V
Voltage for Gain 200: T = +20 °C: 398.6388213 V     T = -25 °C: 362.3317141 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.471852993 V-1     T = -25 °C: 4.62615047 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.724648328 V-1     T = -25 °C: 9.230873695 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.18359049 V-1     T = -25 °C: 14.49236603 V-1
Break-through voltage: T = +20 °C: 413.2058744 V     T = -25 °C: 377.3196509 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:31:14 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:14:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:18:02 CET jreher Updated box and position via API.
11. Aug 2020 17:41:03 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:27 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:42 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:03:53 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:03 CET jreher Updated irradiation info via API.
16. Jan 2020 11:57:57 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:08 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:54 CET jreher Updated APD location via API.
25. Nov 2019 17:28:48 CET jreher Updated box and position via API.
22. Oct 2019 13:37:32 CEST spankonin Updated APD location via API.
22. Oct 2019 12:50:38 CEST spankonin Updated APD location via API.
18. Oct 2019 13:58:53 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:59:13 CEST Tobias Imported from Hamamatsu datasheet.