Show Hamamatsu Avalanche Photo Diode 2313025271 - Archived data from Thu, 16. January 2020 11:57:03 CET
This is all the information about APD 2313025271. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2313025271 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C10 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 382.4 V |
| Dark current: | 4.3 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 233 |
| Position in Box: | 45 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 21. Aug 2019 |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:18:22 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:41:57 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:29:50 CEST | jreher | Updated box and position via API. |
| 03. Apr 2020 09:45:26 CEST | jreher | Assigned to capsule by script |
| 13. Feb 2020 14:23:20 CET | jreher | Updated box and position via API. |
| 16. Jan 2020 12:05:38 CET | jreher | Updated date sent for analysis after screening via API. |
| 16. Jan 2020 12:03:49 CET | jreher | Updated annealing info via API. |
| 16. Jan 2020 12:00:59 CET | jreher | Updated irradiation info via API. |
| 16. Jan 2020 11:57:49 CET | jreher | Updated arrival for irradiation via API. |
| 16. Jan 2020 11:57:03 CET | jreher | Updated arrival for irradiation via API. |
| 27. Nov 2019 20:10:19 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:29:01 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 13:08:19 CEST | spankonin | Updated APD location via API. |
| 18. Oct 2019 14:14:34 CEST | jgrochowski | Updated APD batch assignment via API. |
| 23. Jun 2016 11:59:11 CEST | Tobias | Imported from Hamamatsu datasheet. |