RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0721006948 - Archived data from Wed, 03. February 2021 18:20:39 CET


This is all the information about APD 0721006948. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0721006948
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.9 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 52
Position in Box: 36
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.6350931 V     T = -25 °C: 350.0305385 V
Voltage for Gain 150: T = +20 °C: 393.4796111 V     T = -25 °C: 357.4838625 V
Voltage for Gain 200: T = +20 °C: 397.9449966 V     T = -25 °C: 361.7142402 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.222979282 V-1     T = -25 °C: 4.795013101 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.206442932 V-1     T = -25 °C: 9.698420011 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.27807913 V-1     T = -25 °C: 15.68838116 V-1
Break-through voltage: T = +20 °C: 412.54372 V     T = -25 °C: 376.3095626 V
   
Notes:


Version history

Time Author Change comment
14. Apr 2021 14:20:29 CEST jreher Assigned to capsule by script
16. Feb 2021 12:28:30 CET jreher Updated box and position via API.
05. Feb 2021 10:55:04 CET jreher Updated box and position via API.
03. Feb 2021 18:20:39 CET jreher Updated box and position via API.
11. Aug 2020 17:27:32 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:54 CET jreher Updated APD location via API.
25. Nov 2019 17:15:02 CET jreher Updated box and position via API.
04. Jul 2019 11:12:19 CEST jreher Updated APD location via API.
17. Jun 2019 17:50:59 CEST spankonin Updated APD batch assignment via API.
04. Jun 2019 15:25:32 CEST markus.moritz
22. Jun 2016 15:13:22 CEST Tobias Imported from Hamamatsu datasheet.