RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2310025013 - Archived data from Fri, 18. December 2020 14:01:21 CET


This is all the information about APD 2310025013. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2310025013
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 378.9 V
Dark current: 8.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 219
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.6071566 V     T = -25 °C: 343.3804221 V
Voltage for Gain 150: T = +20 °C: 386.4808098 V     T = -25 °C: 350.7648347 V
Voltage for Gain 200: T = +20 °C: 390.8689795 V     T = -25 °C: 354.9098318 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.375170555 V-1     T = -25 °C: 4.750848062 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.434240761 V-1     T = -25 °C: 9.677371258 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.51218975 V-1     T = -25 °C: 15.30475644 V-1
Break-through voltage: T = +20 °C: 406.771658 V     T = -25 °C: 370.4558404 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:45:22 CEST oafedulidis Assigned to capsule by script
05. Feb 2021 11:16:34 CET jreher Updated box and position via API.
18. Dec 2020 14:01:21 CET jreher Updated box and position via API.
11. Aug 2020 17:44:30 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:27:28 CEST jreher Updated box and position via API.
27. Nov 2019 20:07:45 CET jreher Updated APD location via API.
25. Nov 2019 17:27:58 CET jreher Updated box and position via API.
31. Oct 2019 17:01:36 CET spankonin Updated APD location via API.
31. Oct 2019 16:32:47 CET jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:59:04 CEST Tobias Imported from Hamamatsu datasheet.