Subdetector specification:  
Serial: 2304024414
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2805031190/2304024414
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 270
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.0882494 V     T = -25 °C: 346.5277203 V
Voltage for Gain 150: T = +20 °C: 389.8923745 V     T = -25 °C: 353.9126359 V
Voltage for Gain 200: T = +20 °C: 394.2415805 V     T = -25 °C: 358.0506648 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.613393491 V-1     T = -25 °C: 4.723131276 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.090734947 V-1     T = -25 °C: 9.584990756 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.16074671 V-1     T = -25 °C: 15.12710971 V-1
Break-through voltage: T = +20 °C: 409.7491873 V     T = -25 °C: 373.3280783 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:09 CET jreher Updated box and position via API.
11. Aug 2020 17:46:19 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:13 CEST jreher Updated box and position via API.
31. Mar 2020 08:53:15 CEST jreher Assigned to capsule by script
13. Feb 2020 14:22:31 CET jreher Updated box and position via API.
13. Feb 2020 14:22:19 CET jreher Updated box and position via API.
27. Nov 2019 20:16:07 CET jreher Updated APD location via API.
25. Nov 2019 17:30:49 CET jreher Updated box and position via API.
14. Nov 2019 17:29:51 CET spankonin Updated APD batch assignment via API.
14. Nov 2019 17:27:00 CET spankonin Updated APD location via API.
23. Jun 2016 11:58:01 CEST Tobias Imported from Hamamatsu datasheet.