RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0718006777 - Archived data from Tue, 11. August 2020 17:36:04 CEST


This is all the information about APD 0718006777. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0718006777
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0718006777/2609029843
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: B10
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.1 V
Dark current: 11.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 198
Position in Box: 22
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.1866724 V     T = -25 °C: 347.7624145 V
Voltage for Gain 150: T = +20 °C: 391.0218811 V     T = -25 °C: 355.1167255 V
Voltage for Gain 200: T = +20 °C: 395.3972773 V     T = -25 °C: 359.2594905 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.480999005 V-1     T = -25 °C: 4.929699267 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.747318903 V-1     T = -25 °C: 9.235464298 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.14062456 V-1     T = -25 °C: 16.23061944 V-1
Break-through voltage: T = +20 °C: 408.0370017 V     T = -25 °C: 374.6844147 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:13:56 CET jreher Updated box and position via API.
11. Aug 2020 17:36:04 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:53:00 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:01 CET jreher Updated box and position via API.
27. Nov 2019 20:04:08 CET jreher Updated APD location via API.
25. Nov 2019 17:26:29 CET jreher Updated box and position via API.
13. Aug 2019 14:44:27 CEST spankonin Updated APD batch assignment via API.
07. Aug 2019 13:48:19 CEST markus.moritz
22. Jun 2016 15:13:18 CEST Tobias Imported from Hamamatsu datasheet.