RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2009022161 - Archived data from Tue, 06. October 2020 16:53:08 CEST


This is all the information about APD 2009022161. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2009022161
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.3 V
Dark current: 18.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 234
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.8716519 V     T = -25 °C: 349.8699567 V
Voltage for Gain 150: T = +20 °C: 392.7175932 V     T = -25 °C: 357.2138979 V
Voltage for Gain 200: T = +20 °C: 397.0761374 V     T = -25 °C: 361.3543628 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.672221186 V-1     T = -25 °C: 5.010003986 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.242250193 V-1     T = -25 °C: 9.307501442 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.37333535 V-1     T = -25 °C: 14.61878006 V-1
Break-through voltage: T = +20 °C: 412.0328136 V     T = -25 °C: 376.1396894 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:30 CET jreher Updated box and position via API.
08. Dec 2020 17:18:00 CET jreher Assigned to capsule by script
06. Oct 2020 16:53:08 CEST jreher Updated box and position via API.
11. Aug 2020 17:41:29 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:01 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:36 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:47 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:57 CET jreher Updated irradiation info via API.
16. Jan 2020 11:59:04 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:58:18 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:30 CET jreher Updated APD location via API.
25. Nov 2019 17:29:06 CET jreher Updated box and position via API.
22. Oct 2019 12:56:12 CEST spankonin Updated APD location via API.
18. Oct 2019 14:06:40 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:53:48 CEST Tobias Imported from Hamamatsu datasheet.