RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2009022148 - Archived data from Fri, 05. February 2021 11:18:10 CET


This is all the information about APD 2009022148. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2009022148
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B11
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 13.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 232
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2602191 V     T = -25 °C: 345.7725322 V
Voltage for Gain 150: T = +20 °C: 388.0396058 V     T = -25 °C: 353.0065881 V
Voltage for Gain 200: T = +20 °C: 392.4061836 V     T = -25 °C: 357.0726544 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.588426793 V-1     T = -25 °C: 5.130329357 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.993489469 V-1     T = -25 °C: 9.671457579 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.88736689 V-1     T = -25 °C: 15.38311376 V-1
Break-through voltage: T = +20 °C: 406.7010232 V     T = -25 °C: 371.0735779 V
   
Notes:


Version history

Time Author Change comment
27. Oct 2021 14:17:52 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:04 CEST jreher Updated box and position via API.
05. Feb 2021 11:18:10 CET jreher Updated box and position via API.
11. Aug 2020 17:41:31 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:36 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:35 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:46 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:56 CET jreher Updated irradiation info via API.
16. Jan 2020 11:59:03 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:58:16 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:05 CET jreher Updated APD location via API.
25. Nov 2019 17:28:53 CET jreher Updated box and position via API.
22. Oct 2019 12:56:45 CEST spankonin Updated APD location via API.
18. Oct 2019 14:06:40 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:53:48 CEST Tobias Imported from Hamamatsu datasheet.