Subdetector specification:  
Serial: 2008022020
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H06
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.3 V
Dark current: 10.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 231
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.2147202 V     T = -25 °C: 343.0873615 V
Voltage for Gain 150: T = +20 °C: 384.996619 V     T = -25 °C: 350.3002587 V
Voltage for Gain 200: T = +20 °C: 389.3787598 V     T = -25 °C: 354.3713695 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.565996586 V-1     T = -25 °C: 5.000346229 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.894674799 V-1     T = -25 °C: 9.302431213 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.43342013 V-1     T = -25 °C: 16.73613835 V-1
Break-through voltage: T = +20 °C: 404.7185206 V     T = -25 °C: 369.1600311 V
   
Notes:


Version history

Time Author Change comment
16. May 2022 13:33:11 CEST oafedulidis Updated box and position via API.
28. Apr 2021 13:29:34 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:18:01 CET jreher Updated box and position via API.
11. Aug 2020 17:41:02 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:26 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:29 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:39 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:49 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:57 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:58:04 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:53 CET jreher Updated APD location via API.
25. Nov 2019 17:28:48 CET jreher Updated box and position via API.
22. Oct 2019 13:37:31 CEST spankonin Updated APD location via API.
22. Oct 2019 12:50:38 CEST spankonin Updated APD location via API.
18. Oct 2019 13:57:52 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:52:50 CEST Tobias Imported from Hamamatsu datasheet.