| Subdetector specification: | |
|---|---|
| Serial: | 2008022020 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H06 |
| Break-through voltage: | 405 V |
| Voltage for Gain 100 (T=+25°C): | 377.3 V |
| Dark current: | 10.8 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 231 |
| Position in Box: | 4 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 21. Aug 2019 |
| Sent for analysis after irradiation: | 15. Oct 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 09. Oct 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 12. Oct 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 377.2147202 V T = -25 °C: 343.0873615 V |
| Voltage for Gain 150: | T = +20 °C: 384.996619 V T = -25 °C: 350.3002587 V |
| Voltage for Gain 200: | T = +20 °C: 389.3787598 V T = -25 °C: 354.3713695 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.565996586 V-1 T = -25 °C: 5.000346229 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.894674799 V-1 T = -25 °C: 9.302431213 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.43342013 V-1 T = -25 °C: 16.73613835 V-1 |
| Break-through voltage: | T = +20 °C: 404.7185206 V T = -25 °C: 369.1600311 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 16. May 2022 13:33:11 CEST | oafedulidis | Updated box and position via API. |
| 28. Apr 2021 13:29:34 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 11:18:01 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:41:02 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:29:26 CEST | jreher | Updated box and position via API. |
| 16. Jan 2020 12:06:29 CET | jreher | Updated date sent for analysis after screening via API. |
| 16. Jan 2020 12:04:39 CET | jreher | Updated annealing info via API. |
| 16. Jan 2020 12:01:49 CET | jreher | Updated irradiation info via API. |
| 16. Jan 2020 11:58:57 CET | jreher | Updated arrival for irradiation via API. |
| 16. Jan 2020 11:58:04 CET | jreher | Updated arrival for irradiation via API. |
| 27. Nov 2019 20:09:53 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:28:48 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 13:37:31 CEST | spankonin | Updated APD location via API. |
| 22. Oct 2019 12:50:38 CEST | spankonin | Updated APD location via API. |
| 18. Oct 2019 13:57:52 CEST | jgrochowski | Updated APD batch assignment via API. |
| 23. Jun 2016 11:52:50 CEST | Tobias | Imported from Hamamatsu datasheet. |