RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0718006716 - Archived data from Tue, 11. August 2020 17:35:30 CEST


This is all the information about APD 0718006716. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0718006716
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2408026543/0718006716
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380 V
Dark current: 17.3 nA
   
Screening Logistics:  
Available: No
Storage Box: 194
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.1772955 V     T = -25 °C: 345.2486003 V
Voltage for Gain 150: T = +20 °C: 388.0131928 V     T = -25 °C: 352.5773641 V
Voltage for Gain 200: T = +20 °C: 392.3881259 V     T = -25 °C: 356.6686398 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.58162181 V-1     T = -25 °C: 4.866005802 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.95212591 V-1     T = -25 °C: 10.00204955 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.86909301 V-1     T = -25 °C: 16.07621224 V-1
Break-through voltage: T = +20 °C: 407.8517868 V     T = -25 °C: 371.7833085 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:13:23 CET jreher Updated box and position via API.
11. Aug 2020 17:35:30 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:22:02 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:41 CET jreher Updated box and position via API.
27. Nov 2019 20:03:24 CET jreher Updated APD location via API.
25. Nov 2019 17:26:09 CET jreher Updated box and position via API.
16. Aug 2019 12:20:58 CEST jreher Updated APD location via API.
09. Aug 2019 16:47:37 CEST jreher Updated APD batch assignment via API.
09. Aug 2019 16:41:28 CEST jreher Updated APD batch assignment via API.
09. Aug 2019 16:35:29 CEST jreher Updated APD batch assignment via API.
31. Jul 2019 14:42:26 CEST markus.moritz
22. Jun 2016 15:13:17 CEST Tobias Imported from Hamamatsu datasheet.