Show Hamamatsu Avalanche Photo Diode 2002021608 - Archived data from Tue, 11. August 2020 17:43:06 CEST
This is all the information about APD 2002021608. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2002021608 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | G04 |
| Break-through voltage: | 410 V |
| Voltage for Gain 100 (T=+25°C): | 381.7 V |
| Dark current: | 17.2 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 236 |
| Position in Box: | 32 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 21. Aug 2019 |
| Sent for analysis after irradiation: | 15. Oct 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 09. Oct 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 12. Oct 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 382.4178725 V T = -25 °C: 346.742187 V |
| Voltage for Gain 150: | T = +20 °C: 390.3712237 V T = -25 °C: 354.2327899 V |
| Voltage for Gain 200: | T = +20 °C: 394.7909315 V T = -25 °C: 358.468478 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.409816126 V-1 T = -25 °C: 4.97486875 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.570811878 V-1 T = -25 °C: 9.094121244 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.6812936 V-1 T = -25 °C: 15.96442209 V-1 |
| Break-through voltage: | T = +20 °C: 410.1008959 V T = -25 °C: 373.7479707 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:18:44 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:43:06 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:30:21 CEST | jreher | Updated box and position via API. |
| 16. Jan 2020 12:06:10 CET | jreher | Updated date sent for analysis after screening via API. |
| 16. Jan 2020 12:04:21 CET | jreher | Updated annealing info via API. |
| 16. Jan 2020 12:01:31 CET | jreher | Updated irradiation info via API. |
| 16. Jan 2020 11:58:39 CET | jreher | Updated arrival for irradiation via API. |
| 16. Jan 2020 11:57:38 CET | jreher | Updated arrival for irradiation via API. |
| 27. Nov 2019 20:10:51 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:29:14 CET | jreher | Updated box and position via API. |
| 22. Oct 2019 16:36:56 CEST | spankonin | Updated APD batch assignment via API. |
| 22. Oct 2019 16:17:10 CEST | spankonin | Updated APD location via API. |
| 23. Jun 2016 11:52:40 CEST | Tobias | Imported from Hamamatsu datasheet. |