RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1913021244 - Archived data from Tue, 08. December 2020 17:07:03 CET


This is all the information about APD 1913021244. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1913021244
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2311025051/1913021244
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.3 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 271
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.1233479 V     T = -25 °C: 349.3923397 V
Voltage for Gain 150: T = +20 °C: 392.9277367 V     T = -25 °C: 356.8782291 V
Voltage for Gain 200: T = +20 °C: 397.2647996 V     T = -25 °C: 361.0863521 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.561708148 V-1     T = -25 °C: 4.683593644 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.992677128 V-1     T = -25 °C: 9.362054543 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.02437371 V-1     T = -25 °C: 14.65053074 V-1
Break-through voltage: T = +20 °C: 412.3681891 V     T = -25 °C: 376.3846358 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:18 CET jreher Updated box and position via API.
08. Dec 2020 17:07:03 CET jreher Assigned to capsule by script
17. Aug 2020 16:01:00 CEST vwerner Updated box and position via API.
11. Aug 2020 17:49:57 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:25 CEST jreher Updated box and position via API.
27. Nov 2019 20:16:19 CET jreher Updated APD location via API.
25. Nov 2019 17:30:54 CET jreher Updated box and position via API.
25. Nov 2019 17:14:10 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:57 CEST Tobias Imported from Hamamatsu datasheet.