Show Hamamatsu Avalanche Photo Diode 0717006643 - Archived data from Wed, 22. June 2016 15:13:16 CEST
					This is all the information about APD 0717006643. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 0717006643 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | G03 | 
| Break-through voltage: | 416 V | 
| Voltage for Gain 100 (T=+25°C): | 387.3 V | 
| Dark current: | 15 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 299 | 
| Position in Box: | 21 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | none | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 16. Nov 2021 10:41:35 CET | oafedulidis | Assigned to capsule by script | 
| 27. Aug 2021 10:31:10 CEST | oafedulidis | Updated box and position via API. | 
| 05. Feb 2021 11:26:52 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 17:57:00 CEST | jreher | Updated APD characteristics via API. | 
| 21. Jul 2020 14:42:40 CEST | jreher | Updated APD location via API. | 
| 21. Jul 2020 14:42:31 CEST | jreher | Updated box and position via API. | 
| 19. Dec 2019 15:51:13 CET | spankonin | Updated APD batch assignment via API. | 
| 19. Dec 2019 15:17:43 CET | jreher | Updated box and position via API. | 
| 10. Aug 2017 14:50:33 CEST | hans-georg.zaunick | Entered shipped after irradiation date. | 
| 08. Aug 2017 17:56:14 CEST | hans-georg.zaunick | Entered irradiation information. | 
| 07. Aug 2017 16:55:31 CEST | hans-georg.zaunick | Entered arrival for irradiation date. | 
| 07. Aug 2017 16:48:59 CEST | hans-georg.zaunick | Entered arrival for irradiation date. | 
| 04. Aug 2017 03:15:11 CEST | Tobias | Assigned to grid via information extracted from APD DB. | 
| 22. Jun 2016 15:13:16 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					