RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1905020606 - Archived data from Tue, 11. August 2020 18:09:54 CEST


This is all the information about APD 1905020606. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1905020606
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F02
Break-through voltage: 397 V
Voltage for Gain 100 (T=+25°C): 368.7 V
Dark current: 12.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 269
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 374.3818725 V     T = -25 °C: 334.7070997 V
Voltage for Gain 150: T = +20 °C: 381.053495 V     T = -25 °C: 342.0317361 V
Voltage for Gain 200: T = +20 °C: 384.7277669 V     T = -25 °C: 346.1843532 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.186248434 V-1     T = -25 °C: 5.093950051 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 10.3782334 V-1     T = -25 °C: 9.441718589 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 17.49618729 V-1     T = -25 °C: 14.81626371 V-1
Break-through voltage: T = +20 °C: 395.7329651 V     T = -25 °C: 360.705858 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:58 CET jreher Updated box and position via API.
11. Aug 2020 18:09:54 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:06 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:57 CEST jreher Updated box and position via API.
29. Jun 2020 16:12:22 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:52 CEST Tobias Imported from Hamamatsu datasheet.