Subdetector specification:  
Serial: 1903020522
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H07
Break-through voltage: 401 V
Voltage for Gain 100 (T=+25°C): 372.9 V
Dark current: 11.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 267
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 396.1533529 V     T = -25 °C: 338.0408862 V
Voltage for Gain 150: T = +20 °C: 396.1559053 V     T = -25 °C: 345.4768041 V
Voltage for Gain 200: T = +20 °C: 396.1584577 V     T = -25 °C: 349.6784945 V
Gain/Voltage slope at M = 100: T = +20 °C: 19589.34196 V-1     T = -25 °C: 4.919684026 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 19589.34196 V-1     T = -25 °C: 8.999094703 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 19589.34196 V-1     T = -25 °C: 15.69404333 V-1
Break-through voltage: T = +20 °C: 395.6495491 V     T = -25 °C: 364.7106838 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:10 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:33:50 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:33:27 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:22:42 CET jreher Updated box and position via API.
07. Oct 2020 15:44:33 CEST jreher Updated APD location via API.
11. Aug 2020 18:08:57 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:42 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:33 CEST jreher Updated box and position via API.
29. Jun 2020 16:08:47 CEST jreher Updated APD batch assignment via API.
29. Jun 2020 15:57:07 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:50 CEST Tobias Imported from Hamamatsu datasheet.