RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1804020306 - Archived data from Tue, 11. August 2020 18:08:49 CEST


This is all the information about APD 1804020306. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1804020306
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 433 V
Voltage for Gain 100 (T=+25°C): 404.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 330
Position in Box: 22
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 404.7339573 V     T = -25 °C: 368.1272487 V
Voltage for Gain 150: T = +20 °C: 412.6310352 V     T = -25 °C: 375.9569076 V
Voltage for Gain 200: T = +20 °C: 416.9997695 V     T = -25 °C: 380.3192628 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.65517873 V-1     T = -25 °C: 4.573651375 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.26037914 V-1     T = -25 °C: 9.022253204 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.48306045 V-1     T = -25 °C: 14.03051137 V-1
Break-through voltage: T = +20 °C: 428.1040657 V     T = -25 °C: 396.3641733 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:30:42 CET jreher Updated box and position via API.
11. Aug 2020 18:08:49 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:21 CEST jreher Updated APD location via API.
21. Jul 2020 14:46:11 CEST jreher Updated box and position via API.
29. Jun 2020 16:08:25 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:45 CEST Tobias Imported from Hamamatsu datasheet.