RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1720019926 - Archived data from Tue, 11. August 2020 18:10:10 CEST


This is all the information about APD 1720019926. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1720019926
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 398.5 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 275
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.3255934 V     T = -25 °C: 362.6648723 V
Voltage for Gain 150: T = +20 °C: 407.2060124 V     T = -25 °C: 370.4206314 V
Voltage for Gain 200: T = +20 °C: 411.5864647 V     T = -25 °C: 374.7339322 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.47999344 V-1     T = -25 °C: 4.464894912 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.75920158 V-1     T = -25 °C: 8.683738904 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.28579452 V-1     T = -25 °C: 15.13336489 V-1
Break-through voltage: T = +20 °C: 428.3234241 V     T = -25 °C: 390.5166881 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:48 CET jreher Updated box and position via API.
11. Aug 2020 18:10:10 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:37:26 CEST jreher Updated APD location via API.
21. Jul 2020 14:37:16 CEST jreher Updated box and position via API.
29. Jun 2020 16:14:05 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:47:35 CEST Tobias Imported from Hamamatsu datasheet.