RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1716019614 - Archived data from Tue, 11. August 2020 17:52:18 CEST


This is all the information about APD 1716019614. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1716019614
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A08
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 394 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 278
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.8740681 V     T = -25 °C: 357.196084 V
Voltage for Gain 150: T = +20 °C: 401.8467532 V     T = -25 °C: 364.92355 V
Voltage for Gain 200: T = +20 °C: 406.2891057 V     T = -25 °C: 369.2783843 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.536255274 V-1     T = -25 °C: 4.642386404 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.88095222 V-1     T = -25 °C: 9.06030115 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.69929862 V-1     T = -25 °C: 13.99084633 V-1
Break-through voltage: T = +20 °C: 420.4386112 V     T = -25 °C: 384.5134079 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:14 CET jreher Updated box and position via API.
11. Aug 2020 17:52:18 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:11 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:02 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:16 CET jreher Updated box and position via API.
05. Dec 2019 17:42:35 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:38 CEST Tobias Imported from Hamamatsu datasheet.