Subdetector specification:  
Serial: 1716019578
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 395.6 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 277
Position in Box: 3
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 396.2065532 V     T = -25 °C: 359.8482915 V
Voltage for Gain 150: T = +20 °C: 404.1089199 V     T = -25 °C: 367.5741663 V
Voltage for Gain 200: T = +20 °C: 408.4886877 V     T = -25 °C: 371.8927087 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.545360205 V-1     T = -25 °C: 4.765115179 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.945713013 V-1     T = -25 °C: 8.688351221 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.98232471 V-1     T = -25 °C: 15.12382929 V-1
Break-through voltage: T = +20 °C: 423.7094162 V     T = -25 °C: 387.7804466 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:01 CET jreher Updated box and position via API.
11. Aug 2020 17:51:57 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:37:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:37:43 CEST jreher Updated box and position via API.
12. Dec 2019 12:43:04 CET spankonin Updated box and position via API.
05. Dec 2019 18:02:10 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:37 CEST Tobias Imported from Hamamatsu datasheet.