Show Hamamatsu Avalanche Photo Diode 1715019547 - Archived data from Tue, 11. August 2020 17:52:00 CEST


This is all the information about APD 1715019547. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1715019547
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 395.2 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 277
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 395.8478813 V     T = -25 °C: 359.3427308 V
Voltage for Gain 150: T = +20 °C: 403.7642988 V     T = -25 °C: 367.0888993 V
Voltage for Gain 200: T = +20 °C: 408.1649143 V     T = -25 °C: 371.4441166 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.608668442 V-1     T = -25 °C: 4.582030025 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.095358922 V-1     T = -25 °C: 8.955264312 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.12126793 V-1     T = -25 °C: 15.68050495 V-1
Break-through voltage: T = +20 °C: 423.8142045 V     T = -25 °C: 387.5120611 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:02 CET jreher Updated box and position via API.
11. Aug 2020 17:52:00 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:37:54 CEST jreher Updated APD location via API.
21. Jul 2020 14:37:44 CEST jreher Updated box and position via API.
12. Dec 2019 12:43:05 CET spankonin Updated box and position via API.
05. Dec 2019 18:02:11 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:36 CEST Tobias Imported from Hamamatsu datasheet.