RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1715019531 - Archived data from Tue, 11. August 2020 17:52:25 CEST


This is all the information about APD 1715019531. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1715019531
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 389.9 V
Dark current: 3.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 279
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.4642967 V     T = -25 °C: 354.2065331 V
Voltage for Gain 150: T = +20 °C: 398.3247311 V     T = -25 °C: 361.8226655 V
Voltage for Gain 200: T = +20 °C: 402.6849324 V     T = -25 °C: 366.1025569 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.424810597 V-1     T = -25 °C: 4.68302535 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.676509165 V-1     T = -25 °C: 9.276300212 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.11522471 V-1     T = -25 °C: 14.51155281 V-1
Break-through voltage: T = +20 °C: 414.4011017 V     T = -25 °C: 382.2236188 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:20 CET jreher Updated box and position via API.
11. Aug 2020 17:52:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:26 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:16 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:22 CET jreher Updated box and position via API.
05. Dec 2019 17:41:41 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:36 CEST Tobias Imported from Hamamatsu datasheet.