RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1715019526 - Archived data from Tue, 11. August 2020 17:52:24 CEST


This is all the information about APD 1715019526. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1715019526
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.7 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 279
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.5804369 V     T = -25 °C: 355.1920733 V
Voltage for Gain 150: T = +20 °C: 399.4548726 V     T = -25 °C: 362.8452979 V
Voltage for Gain 200: T = +20 °C: 403.8124177 V     T = -25 °C: 367.1439361 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.412042138 V-1     T = -25 °C: 4.687314561 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.591055545 V-1     T = -25 °C: 9.282844075 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.89022297 V-1     T = -25 °C: 14.45634464 V-1
Break-through voltage: T = +20 °C: 417.2983675 V     T = -25 °C: 383.0789358 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:29:24 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:10:47 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:24:19 CET jreher Updated box and position via API.
11. Aug 2020 17:52:24 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:25 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:15 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:22 CET jreher Updated box and position via API.
05. Dec 2019 17:41:41 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:36 CEST Tobias Imported from Hamamatsu datasheet.