RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1713019353 - Archived data from Tue, 11. August 2020 17:50:41 CEST


This is all the information about APD 1713019353. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1713019353
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.6 V
Dark current: 3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 260
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.1129205 V     T = -25 °C: 356.7581983 V
Voltage for Gain 150: T = +20 °C: 400.9877384 V     T = -25 °C: 364.4403108 V
Voltage for Gain 200: T = +20 °C: 405.3684165 V     T = -25 °C: 368.7185944 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.546829942 V-1     T = -25 °C: 4.817901665 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.924694859 V-1     T = -25 °C: 8.707897969 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.826727 V-1     T = -25 °C: 15.1654228 V-1
Break-through voltage: T = +20 °C: 416.6484262 V     T = -25 °C: 384.4670818 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:52:44 CET oafedulidis Assigned to capsule by script
09. Dec 2021 13:11:01 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:21:50 CET jreher Updated box and position via API.
11. Aug 2020 17:50:41 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:34:20 CEST jreher Updated box and position via API.
05. Dec 2019 14:37:07 CET jreher Updated box and position via API.
05. Dec 2019 14:35:03 CET spankonin Updated box and position via API.
05. Dec 2019 14:33:06 CET spankonin Updated box and position via API.
03. Dec 2019 14:46:22 CET jreher Updated APD location via API.
02. Dec 2019 19:19:21 CET spankonin Updated box and position via API.
02. Dec 2019 19:12:17 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:33 CEST Tobias Imported from Hamamatsu datasheet.