RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1711019235 - Archived data from Tue, 11. August 2020 17:52:50 CEST


This is all the information about APD 1711019235. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1711019235
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B10
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.7 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 281
Position in Box: 44
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.1185612 V     T = -25 °C: 356.7547341 V
Voltage for Gain 150: T = +20 °C: 401.0573926 V     T = -25 °C: 364.4774074 V
Voltage for Gain 200: T = +20 °C: 405.4719638 V     T = -25 °C: 368.8023334 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.497961482 V-1     T = -25 °C: 4.801915468 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.798363167 V-1     T = -25 °C: 8.623965942 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.37638757 V-1     T = -25 °C: 14.83687069 V-1
Break-through voltage: T = +20 °C: 418.495707 V     T = -25 °C: 384.8957716 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:38 CET jreher Updated box and position via API.
11. Aug 2020 17:52:50 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:56 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:46 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:02 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:04 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:30 CEST Tobias Imported from Hamamatsu datasheet.