RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1711019209 - Archived data from Tue, 11. August 2020 17:53:04 CEST


This is all the information about APD 1711019209. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1711019209
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 422 V
Voltage for Gain 100 (T=+25°C): 392.9 V
Dark current: 3.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 283
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.9234028 V     T = -25 °C: 357.3316736 V
Voltage for Gain 150: T = +20 °C: 401.8341345 V     T = -25 °C: 365.0468931 V
Voltage for Gain 200: T = +20 °C: 406.2369956 V     T = -25 °C: 369.3751889 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.554740068 V-1     T = -25 °C: 4.585170852 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.969420062 V-1     T = -25 °C: 8.916276666 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.82687376 V-1     T = -25 °C: 15.48428828 V-1
Break-through voltage: T = +20 °C: 421.7793137 V     T = -25 °C: 385.3661705 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:49 CET jreher Updated box and position via API.
11. Aug 2020 17:53:04 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:23 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:13 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:53 CET spankonin Updated box and position via API.
09. Dec 2019 18:23:13 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:30 CEST Tobias Imported from Hamamatsu datasheet.