RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1711019207 - Archived data from Tue, 11. August 2020 17:53:12 CEST


This is all the information about APD 1711019207. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1711019207
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.9 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 283
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.8877968 V     T = -25 °C: 356.3792495 V
Voltage for Gain 150: T = +20 °C: 400.8357905 V     T = -25 °C: 364.0468644 V
Voltage for Gain 200: T = +20 °C: 405.2458553 V     T = -25 °C: 368.3669829 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.583969995 V-1     T = -25 °C: 4.6046368 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.028714742 V-1     T = -25 °C: 9.076054029 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.9957681 V-1     T = -25 °C: 14.07247801 V-1
Break-through voltage: T = +20 °C: 420.2492656 V     T = -25 °C: 384.076159 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:54 CET jreher Updated box and position via API.
11. Aug 2020 17:53:12 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:26 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:16 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:56 CET spankonin Updated box and position via API.
09. Dec 2019 18:19:59 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:30 CEST Tobias Imported from Hamamatsu datasheet.