Show Hamamatsu Avalanche Photo Diode 1710019157 - Archived data from Tue, 11. August 2020 17:27:09 CEST
This is all the information about APD 1710019157. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1710019157 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C05 |
| Break-through voltage: | 426 V |
| Voltage for Gain 100 (T=+25°C): | 397.2 V |
| Dark current: | 3.8 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 46 |
| Position in Box: | 6 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 3003 |
| Position in grid: | 0 |
| Arrival for irradiation: | 11. Aug 2016 |
| Sent for analysis after irradiation: | 02. Sep 2016 |
| Return for assembly: | 13. Oct 2016 |
| Irradiation: | |
| Date: | 18. Aug 2016 |
| Dose used: | 30 Gy |
| Temperature: | 25 °C |
| Position: | 2 |
| Bias voltage: | 350 V (connected) |
| Annealing: | |
| Date: | 18. Aug 2016 |
| Temperature: | 80 °C |
| Duration: | 10 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 397.7618902 V T = -25 °C: 360.9419262 V |
| Voltage for Gain 150: | T = +20 °C: 405.7648837 V T = -25 °C: 368.7591363 V |
| Voltage for Gain 200: | T = +20 °C: 410.1866704 V T = -25 °C: 373.1318504 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.521432247 V-1 T = -25 °C: 4.639790809 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.942589932 V-1 T = -25 °C: 9.242879872 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.32477039 V-1 T = -25 °C: 14.3080907 V-1 |
| Break-through voltage: | T = +20 °C: 426.2116467 V T = -25 °C: 389.3317839 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:54:04 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:19:51 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:46:07 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 17:27:09 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:37:08 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:14:32 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:11:51 CEST | jreher | Updated APD location via API. |
| 18. Jun 2019 13:30:06 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Apr 2018 14:03:21 CEST | jgrochowski | |
| 13. Oct 2016 11:50:18 CEST | markus.moritz | Entered return for assembly date. |
| 08. Sep 2016 13:37:21 CEST | markus.moritz | Entered shipped after irradiation date. |
| 24. Aug 2016 14:21:50 CEST | christopher.l.hahn | Entered annealing information. |
| 18. Aug 2016 11:39:27 CEST | markus.moritz | Entered irradiation information. |
| 11. Aug 2016 11:44:28 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:52:14 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 11:42:29 CEST | Tobias | Imported from Hamamatsu datasheet. |