Subdetector specification:  
Serial: 1710019138
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B13
Break-through voltage: 425 V
Voltage for Gain 100 (T=+25°C): 397.7 V
Dark current: 2.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 282
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 397.7377028 V     T = -25 °C: 361.2723196 V
Voltage for Gain 150: T = +20 °C: 405.6575669 V     T = -25 °C: 369.0380921 V
Voltage for Gain 200: T = +20 °C: 410.0428772 V     T = -25 °C: 373.3902077 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.318202414 V-1     T = -25 °C: 4.594234401 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.252737019 V-1     T = -25 °C: 9.005789072 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.47132353 V-1     T = -25 °C: 14.0493856 V-1
Break-through voltage: T = +20 °C: 424.7611662 V     T = -25 °C: 389.1411618 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:41 CET jreher Updated box and position via API.
11. Aug 2020 17:52:52 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:08 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:58 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:12 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:05 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:28 CEST Tobias Imported from Hamamatsu datasheet.