Subdetector specification:  
Serial: 1710019131
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 398.3 V
Dark current: 3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 282
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.374509 V     T = -25 °C: 362.6207895 V
Voltage for Gain 150: T = +20 °C: 407.2970612 V     T = -25 °C: 370.4323032 V
Voltage for Gain 200: T = +20 °C: 411.6875454 V     T = -25 °C: 374.77502 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.435352671 V-1     T = -25 °C: 4.42504376 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.6756786 V-1     T = -25 °C: 8.624203762 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.1410241 V-1     T = -25 °C: 15.01863317 V-1
Break-through voltage: T = +20 °C: 426.9734171 V     T = -25 °C: 390.6009615 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:40 CET jreher Updated box and position via API.
11. Aug 2020 17:52:51 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:08 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:58 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:11 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:05 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:28 CEST Tobias Imported from Hamamatsu datasheet.