RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1709019050 - Archived data from Tue, 11. August 2020 17:52:43 CEST


This is all the information about APD 1709019050. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1709019050
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 426 V
Voltage for Gain 100 (T=+25°C): 397.7 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 281
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 398.5920276 V     T = -25 °C: 361.7882955 V
Voltage for Gain 150: T = +20 °C: 406.508641 V     T = -25 °C: 369.5793682 V
Voltage for Gain 200: T = +20 °C: 410.8756343 V     T = -25 °C: 373.8572839 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.361667363 V-1     T = -25 °C: 4.529294703 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.487108073 V-1     T = -25 °C: 9.519186301 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.69805212 V-1     T = -25 °C: 14.76683792 V-1
Break-through voltage: T = +20 °C: 427.001335 V     T = -25 °C: 389.8586858 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:34 CET jreher Updated box and position via API.
11. Aug 2020 17:52:43 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:44 CEST jreher Updated box and position via API.
09. Dec 2019 18:28:59 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:24 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:26 CEST Tobias Imported from Hamamatsu datasheet.