RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1708019025 - Archived data from Tue, 11. August 2020 17:52:47 CEST


This is all the information about APD 1708019025. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1708019025
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 393.9 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 281
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.4957241 V     T = -25 °C: 357.8332501 V
Voltage for Gain 150: T = +20 °C: 402.4103789 V     T = -25 °C: 365.5525092 V
Voltage for Gain 200: T = +20 °C: 406.7950302 V     T = -25 °C: 369.8619497 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.390707554 V-1     T = -25 °C: 4.756455341 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.516564089 V-1     T = -25 °C: 9.436520416 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.64758235 V-1     T = -25 °C: 14.73705841 V-1
Break-through voltage: T = +20 °C: 422.4468601 V     T = -25 °C: 385.8643476 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:36 CET jreher Updated box and position via API.
11. Aug 2020 17:52:47 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:55 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:45 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:01 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:03 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:25 CEST Tobias Imported from Hamamatsu datasheet.