RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1707018912 - Archived data from Tue, 11. August 2020 17:51:35 CEST


This is all the information about APD 1707018912. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1707018912
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.3 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 273
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.5909528 V     T = -25 °C: 358.082139 V
Voltage for Gain 150: T = +20 °C: 402.521998 V     T = -25 °C: 365.8025018 V
Voltage for Gain 200: T = +20 °C: 406.9070449 V     T = -25 °C: 370.1362372 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.35417706 V-1     T = -25 °C: 4.683179385 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.450424519 V-1     T = -25 °C: 9.224921393 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.57431611 V-1     T = -25 °C: 14.4011603 V-1
Break-through voltage: T = +20 °C: 422.4839151 V     T = -25 °C: 386.190329 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:06:20 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:20 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:59 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:23:34 CET jreher Updated box and position via API.
11. Aug 2020 17:51:35 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:58 CEST jreher Updated APD location via API.
21. Jul 2020 14:36:49 CEST jreher Updated box and position via API.
12. Dec 2019 12:00:48 CET jreher Updated box and position via API.
09. Dec 2019 14:52:41 CET jreher Updated box and position via API.
05. Dec 2019 18:07:39 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:22 CEST Tobias Imported from Hamamatsu datasheet.