| Grid specification: |
|
| Grid number: |
73 |
| Number of APDs: |
20 |
| |
|
| Grid information: |
|
| Arrival for irradiation: |
11. Jun 2016 |
| Date of irradiation: |
21. Jun 2016 |
| Irradiation temperature: |
25 °C |
| Irradiation voltage: |
320 V |
| Irradiation dose: |
37 Gy |
| Irradiation position: |
2 |
| Shipped for annealing/analysis: |
23. Jun 2016 |
| Annealing date: |
21. Jun 2016 |
| Annealing temperature: |
80 °C |
| Annealing duration: |
8 h |
| Return for assembly: |
11. Jul 2016 |
| Operations: |
Enter irradiation data • Enter annealing data • Enter shipment data |
| |
|
| Grid overview: |
|
| Slot 0: |
0818008627 (HV connection unknown) |
| Slot 1: |
0818008638 (HV connection unknown) |
| Slot 2: |
0818008628 (HV connection unknown) |
| Slot 3: |
0818008639 (HV connection unknown) |
| Slot 4: |
0818008629 (HV connection unknown) |
| Slot 5: |
0818008640 (HV connection unknown) |
| Slot 6: |
0818008630 (HV connection unknown) |
| Slot 7: |
0818008641 (HV connection unknown) |
| Slot 8: |
0818008631 (HV connection unknown) |
| Slot 9: |
0818008642 (HV connection unknown) |
| Slot 10: |
0818008633 (HV connection unknown) |
| Slot 11: |
0819008643 (HV connection unknown) |
| Slot 12: |
0818008634 (HV connection unknown) |
| Slot 13: |
0819008644 (HV connection unknown) |
| Slot 14: |
0818008635 (HV connection unknown) |
| Slot 15: |
0819008645 (HV connection unknown) |
| Slot 16: |
0818008636 (HV connection unknown) |
| Slot 17: |
0819008646 (HV connection unknown) |
| Slot 18: |
0818008637 (HV connection unknown) |
| Slot 19: |
0819008647 (HV connection unknown) |