| Grid specification: |
|
| Grid number: |
67 |
| Number of APDs: |
20 |
| |
|
| Grid information: |
|
| Arrival for irradiation: |
15. May 2016 |
| Date of irradiation: |
20. May 2016 |
| Irradiation temperature: |
-25 °C |
| Irradiation voltage: |
320 V |
| Irradiation dose: |
250 Gy |
| Irradiation position: |
1 |
| Shipped for annealing/analysis: |
23. Jun 2016 |
| Annealing date: |
20. May 2016 |
| Annealing temperature: |
80 °C |
| Annealing duration: |
8 h |
| Return for assembly: |
29. Nov 2016 |
| Operations: |
Enter irradiation data • Enter annealing data • Enter shipment data |
| |
|
| Grid overview: |
|
| Slot 0: |
0818008561 (HV connection unknown) |
| Slot 1: |
0818008571 (HV connection unknown) |
| Slot 2: |
0818008562 (HV connection unknown) |
| Slot 3: |
0818008572 (HV connection unknown) |
| Slot 4: |
0818008563 (HV connection unknown) |
| Slot 5: |
0818008573 (HV connection unknown) |
| Slot 6: |
0818008564 (HV connection unknown) |
| Slot 7: |
0818008574 (HV connection unknown) |
| Slot 8: |
0818008565 (HV connection unknown) |
| Slot 9: |
0818008575 (HV connection unknown) |
| Slot 10: |
0818008566 (HV connection unknown) |
| Slot 11: |
0818008576 (HV connection unknown) |
| Slot 12: |
0818008567 (HV connection unknown) |
| Slot 13: |
0818008577 (HV connection unknown) |
| Slot 14: |
0818008568 (HV connection unknown) |
| Slot 15: |
0818008578 (HV connection unknown) |
| Slot 16: |
0818008569 (HV connection unknown) |
| Slot 17: |
0818008580 (HV connection unknown) |
| Slot 18: |
0818008570 (HV connection unknown) |
| Slot 19: |
0818008581 (HV connection unknown) |