RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Grid Overview

Grid specification:  
Grid number: 139
Number of APDs: 15
   
Grid information:  
Arrival for irradiation: 30. Jun 2016
Date of irradiation: 30. Jun 2016
Irradiation temperature: 25 °C
Irradiation voltage: 320 V
Irradiation dose: 30 Gy
Irradiation position: 2
Shipped for annealing/analysis: 08. Jul 2016
Annealing date: 01. Jul 2016
Annealing temperature: 80 °C
Annealing duration: 8 h
Return for assembly: 04. Aug 2016
Operations: Enter irradiation dataEnter annealing dataEnter shipment data
   
Grid overview:  
Slot 0: 0720006867 (HV connection unknown)
Slot 1: 0719006847 (HV connection unknown)
Slot 2: 0720006866 (HV connection unknown)
Slot 3: 0719006848 (HV connection unknown)
Slot 4: 0720006865 (HV connection unknown)
Slot 5: empty
Slot 6: empty
Slot 7: empty
Slot 8: 0720006863 (HV connection unknown)
Slot 9: 0719006851 (HV connection unknown)
Slot 10: 0720006862 (HV connection unknown)
Slot 11: empty
Slot 12: 0720006861 (HV connection unknown)
Slot 13: 0720006853 (HV connection unknown)
Slot 14: 0720006860 (HV connection unknown)
Slot 15: 0720006855 (HV connection unknown)
Slot 16: 0720006859 (HV connection unknown)
Slot 17: 0720006856 (HV connection unknown)
Slot 18: empty
Slot 19: 0720006857 (HV connection unknown)