RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Vacuum Photo Tetrode UA1682 - Archived data from Sun, 11. June 2017 18:26:58 CEST


This is all the information about VPTT UA1682. If it is wrong, edit the data.

Detector specification:  
Serial: UA1682
Type: Hamamatsu Vacuum Photo Tetrode
Unit: assigned to #112 (barcode 1309001156)
Preamp: 866
Nominal Preamp Gain: none
Measured Preamp Gain: none
   
Measured data:  
DC gain @ 750 V: 54.93
DC gain @ 1000 V: 64.66
Anode dark current: 0.028737 nA
Yield: -1
   
Manufacturer information:  
Cathode luminous sensivity: 63.4 μA/lm
Anode luminous sensivity: 3670 μA/lm
Anode dark current: 0 nA
Cathode blue sensivity: 8.57 a.u.
   
Notes:


Version history

Time Author Change comment
17. May 2018 11:18:46 CEST Tobias Uploading preamp gain data into database.
11. Jun 2017 18:26:58 CEST cschnier Assigned to unit by script
16. Jan 2017 11:29:16 CET Tobias Added anode dark current value.
16. Jan 2017 09:46:51 CET Tobias Added DC gain 750+1000
25. Aug 2016 11:19:56 CEST Tobias Imported from CSV file provided by HISKP.